;
 
Create Websire FREE
More Products
More Company
 
 
  MAALAB SCIENTIFIC EQUIPMENT PRIVATE LIMITED
Hyderabad
 
 
 
  • Environmental Testing
  • Material Testing
  • Medical Equipment
  • Engineering Products
  • Contact Us
  •  
    Thermogravimetric Analyzer

    Thermogrvimetric Analyzer

    Thermogravimetric analysis or thermal gravimetric analysis (TGA) is a type of testing performed on samples that determines changes in weight in relation to change in temperature. Such analysis relies on a high degree of precision in three measurements: weight, temperature, and temperature change. As many weight loss curves look similar, the weight loss curve may require transformation before results may be interpreted. A derivative weight loss curve can identify the point where weight loss is most apparent. Again, interpretation is limited without further modifications and deconvolution of the overlapping peaks may be required. To determine composition and purity one must take the mass of the substance in the mixture by using thermal gravimetric analysis. Thermal gravimetric analysis is the act of heating a mixture to a high enough temperature so that one of the components decomposes into a gas, which dissociates into the air. It is a process that utilizes heat and stoichiometry ratios to determine the percent by mass ration of a solute. If the compounds in the mixture that remain are known, then the percentage by mass can be determined by taking the weight of what is left in the mixture and dividing it by the initial mass. Knowing the mass of the original mixture and the total mass of impurities liberating upon heating, the stoichiometric ratio can be used to calculate the percent mass of the substance in a sample. TGA is commonly employed in research and testing to determine characteristics of materials such as polymers, to determine degradation temperatures, absorbed moisture content of materials, the level of inorganic and organic components in materials, decomposition points of explosives, and solvent residues. It is also often used to estimate the corrosion kinetics in high temperature oxidation.
    Simultaneous TGA-DTA/DSC measures both heat flow and weight changes (TGA) in a material as a function of temperature or time in a controlled atmosphere. Simultaneous measurement of these two material properties not only improves productivity but also simplifies interpretation of the results.

    Various models can be provided as per customer’s request. 

     
    Send Email

     
      CONTACT US AT
    MAALAB SCIENTIFIC EQUIPMENT PRIVATE LIMITED
    ADDRESS : 101 & 102, Ram’s Enclave, Opp.Allwyn Bhavan, Erragadda,
    Hyderabad-500018 (Ap)


    Contact : ,

    Send Email


    Send Email

    WEBSITE : www.goldenpages.in/maalabscientificequipment
    Contact Person :


    Mobile : Send SMS
     
    Home | About Us | Products | Contact Us |
     
    Copyrights @
    Maalab Scientific Equipment Private Limited
    Site Designed & Maintained by Aman Infotech
     
     
    Back to Top